Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of Ultramid® B3WM8 BK00102 - PA6-MD40 - BASF

Material Data Center offers the following functions for Ultramid® B3WM8 BK00102:
unit conversion, PDF datasheet print, comparison with other plastics, snap fit calculation, beam deflection calculation, CAE Interfaces

Check here, which other Ultramid B datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
商品の説明文
Ultramid® B3WM8 (8260 HS) BK-102 is a heat stabilized, pigmented black, 40% mineral reinforced PA6 injection molding resin. It possesses high stiffness, dimensional stability and heat resistance combined with excellent processability including low warp and resistance to sink-mark formation. It maintains its inherent chemical resistance to greases, oils and hydrocarbons.

Ultramid® 8260 HS BK-102 is generally recommended for applications such as marine hardware, brackets, fittings, bobbins, office furniture, appliance components, and power tool housings.
機械的特性乾燥/調湿単位テスト基準
ISO データ
引張弾性率 6400 / 3800 MPa ISO 527
破壊応力 85 / 60 MPa ISO 527
破壊ひずみ 10 / 30 % ISO 527
シャルピー衝撃強さ, +23°C 130 / - kJ/m² ISO 179/1eU
ノッチ付きシャルピー衝撃強さ, +23°C 3 / - kJ/m² ISO 179/1eA
熱的特性乾燥/調湿単位テスト基準
ISO データ
溶融温度, 10°C/min 220 / * °C ISO 11357-1/-3
荷重たわみ温度, 1.80 MPa 90 / * °C ISO 75-1/-2
荷重たわみ温度, 0.45 MPa 190 / * °C ISO 75-1/-2
厚さhでの燃焼性 HB / * class IEC 60695-11-10
試験片の厚さ 3.0 / * mm -
Yellow Card 可用 はい / * - -
電気的特性.乾燥/調湿単位テスト基準
ISO データ
体積抵抗率 >1E13 / - Ohm*m IEC 62631-3-1
その他の特性.乾燥/調湿単位テスト基準
吸水率 5.7 / * % Sim. to ISO 62
吸湿率 1.6 / * % Sim. to ISO 62
密度 1490 / * kg/m³ ISO 1183
Processing Recommendation Injection Molding単位テスト基準
Pre-drying - Temperature 80 °C -
Processing humidity ≤0.2 % -
樹脂温度 240 - 280 °C -
金型温度 80 - 95 °C -
機能
 応力-ひずみ. , Ultramid® B3WM8 BK00102 (乾燥), PA6-MD40, BASF
 応力-ひずみ. , Ultramid® B3WM8 BK00102 (調湿), PA6-MD40, BASF
 割線弾性率−ひずみ. , Ultramid® B3WM8 BK00102 (乾燥), PA6-MD40, BASF
 割線弾性率−ひずみ. , Ultramid® B3WM8 BK00102 (調湿), PA6-MD40, BASF
特殊な特性
成形加工法.
射出成形.
納入形状.
ペレット., 黒
領域別の利用可能性
北アメリカ.
その他の情報
村遜速揃
PROCESSING
injection molding, Melt temperature, range: 270 - 295 °C
injection molding, Melt temperature, recommended: 260 °C
injection molding, Mold temperature, range: 80 - 95 °C
injection molding, Mold temperature, recommended: 80 °C
injection molding, Dwell time, thermoplastics: 10 min

PREPROCESSING
Max. Water content: 0.2%
Product is supplied in sealed containers and drying prior to molding is not required. If drying becomes necessary, a dehumidifying or desiccant dryer operating at 80 °C (176 °F) is recommended. Drying time is dependent on moisture level.
Further information concerning safe handling procedures can be obtained from the Material Safety Data Sheet. Alternatively, please contact your BASF representative.

PROCESSING
Melt Temperature 240-280 °C (464-536 °F)
Mold Temperature 80-95 °C (176-203 °F)
Injection and Packing Pressure 35-125 bar (500-1500 psi)

A mold temperature of 80-95 °C (176-203 °F) is recommended, but temperatures of as low as 10 °C (50 °F) can be used where applicable.

Injection pressure controls the filling of the part and should be applied for 90% of ram travel. Packing pressure affects the final part and can be used effectively in controlling sink marks and shrinkage. It should be applied and maintained until the gate area is completely frozen off.

Fast fill rates are recommended to insure uniform melt delivery to the cavity and prevent premature freezing.
Disclaimer
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.